Analyze LED light셲 thermal performance in the air
Analysis Objective

Analyze natural convection heat transfer of LED system in the air.

Assess LED product's thermal safety by measuring the junction temperature.

Analysis Type
Transient flow analysis
General flow module
Heat transfer module
Solid heat transfer module
LED light
Pre Processing

Material heating condition input (heat source)

Floatability consideration through incompressible ideal gas.

Boundary condition:

  • Inlet (speed)
  • Outlet (pressure)
  • Wall (no slip)
LED light CAD model

LED light CAD model

Post Processing

Verify fluid temperature / speed distribution: performance assessment of heat sink

Junction thermal safety assessment by verifying temperature distribution on solid parts.

Temperature distribution on solid parts

Temperature distribution on solid parts

Flux around solid parts

Flux around solid parts

Temperature distribution on entire model

Temperature distribution on entire model

Flux speed distribution

Flux speed distribution

 